For operating versatility, you may choose direct, reverse, and split range modes. Easy access Zero and Span adjustments make bench or field calibration quick and easy. As a result of this flexibility, installation goes faster. And since the Type 950XP is position insensitive, it gives you even more freedom in mounting and connecting to valves and instruments. Optional, field-selectable process output ranges reduce downtime and inventory. Its standard mounting bracket lets you mount it directly on a valve, wall, panel, or pipe. Its small footprint can fit into tight spots. The Type 950XP gives you big flexibility. And because it takes impure air in stride, downtime is reduced, too. Yet because it typically consumes only 0.05 scfm (0.11 m3/hr) at mid range, it not only costs less to buy, it costs less to operate as well. With flow rates up to 12 SCFM (340 Nl/min), the Type 950XP has the muscle to drive large valves and actuators. Advanced circuitry includes electronic feedback control for superior vibration protection and highly accurate output. Its NEMA 4X (IP65) housing is designed for both Intrinsically Safe* and Explosion-Proof* operation. The Type 950XP converts an electrical current signal to a stable, pneumatic output to actuate valves. 7 W Max.Now there’s a compact I/P transducer that delivers reliable high performance for the toughest applications in the most hazardous environments: the Type 950XP from ControlAir. 7 wĪTEX Approval FM06ATEX0018X II 2 G Ex d IIB + H2 T6 Ta = -20☌ to +70☌ FM06ATEX0027X II 1 G Ex ia IIB T4 Ta = -40☌ to +70☌ FM06ATEX0028X II 3 G Ex nA nL IIC T6 Ta = -40☌ to +70☌Įntity Parameters Ui (Vmax) = 30 VDC Ci = 0 uF Ii (Imax) = 125 mA Li = 0 mH Pi =. Code T6 Ta = 70° CĮntity Parameters U: (Vmax) = 30 VDC Ci = 0 uF I: (Imax) = 125 mA Li = 0 m H Pi =. Suitable for Class II & III, Division 2, Groups F & G Enclosure Nema 4X(IP 65) Temp. Non-Incendive Class I, Division 2, Groups A, B, C & D Enclosure Nema 4X(IP 65) Temp. Intrinsically Safe Class I, Division 1, Groups C & D Class II, Division 1, Groups E, F, & G Class III, Division 1, Fibers Enclosure Nema 4X(IP 65) Rated 4-20 mA, 30 VDC Max. Code T6 Ta = 70° Cĭust Ignition Proof Class II & III, Division 1, Groups E, F & G Enclosure Nema 4X(IP 65) Temp. HAZARDOUS AREA CLASSIFICATION Factory Mutual (FM) & Canadian Standards Approval (CSA)Įxplosion Proof Class I, Division 1 & 2, Groups B, C & D Enclosure Nema 4X (IP 65) Temp. Trim: stainless steel Brass Zinc plated steel. Materials: Housing Chromate-treated aluminium with epoxy baked paint NEMA 4X (IP 65). Media: clean dry, oil free, air filtered to 40 micron. Reverse polarity effect: No damage from reversal of normal supply current (4-20 mA) or from misapplication of up to 60 mA. Supply pressure effect: Not noticeable effect. Vibration effect: Less than ☑% of span under the following conditions: 5-15 in, constant displacement 15-500 Hz g's. Operating modes: direct, reverse or split range.Īccuracy, Hysteresis and repeatability: ☐,1% of span. Supply pressure: 100 PSIG (7,0 bar) maximum (Note supply pressure must be a minimum of 5 PSIG above maximum output)įlow capacity: 4,5 SCFM (7,6 M3/HR) at 25 PSIG (1,7 bar) supply. Air consumption: 3.0 scfh (0,11 m3/hr) at mid range
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |